Our hours are 8:00am to 4:30pm Eastern Standard Time
|
||
![]() |
| The only Patio Plus heater manufactured in Canada |
![]()
Feel The Warmth Of The Summer Sun......
No Matter What the Season!
Patio Plus Heaters...
|
![]()
Portable Model - 50,000 BTU Propane
|
![]() ![]() |
Free Standing Models A portable heater on a weighted base for use with an approved flexible gas connector connected to a natural gas or liquid propane gas supply. Push button spark igniter, no electrical connection required. Have a gas outlet on your deck, and one by the pool! - Assembles & disassembles in minutes for easy storage |
|
Patio Heater Wheel Kit
PHWK1

Safely and convienently move your Patio Plus portable and freestanding
patio heaters with the Easy Radiant Works wheel kit!
The wheel kit can be used on many other makes and models of patio heaters,
and unlike most patio heater wheels, are not fastened to the unit.
One set is all you need for moving all of your patio heaters!
Stationary Models
FIXED BASE and INGROUND
These models are designed for permanent installation.
All stationary models are available with either a manual piezo spark igniter,
24volt standing pilot, or 24 volt direct lite ignition to the burner.
Direct lite models have no standing pilot light
All 24 volt models are controlled by a 120 volt switch to 20 va 120 volts to 24 volt transformer.
A factory installed 24volt remote control control is optional.
![]() |
![]() |
Fixed Base PH-45-FB-LP & PH-50-FB-N |
In Ground PH-45-IG-LP & PH-50-IG-N |
Hanging
PH-45-H-LP and PH-50-H-N

| Permanently installed hanging model with push button spark igniter or 24v direct light - no standing pilot. For hanging installation below a suitable structure. Gas piped from natural gas source or bulk propane. |

Also ideal for outdoor use is our "Equator" model outdoor heater.

More Patio Pictures |
|||||||||||||||||||
| Heat Pattern | ||
| Clearance to Combustibles Above Reflector 18'' Beside Reflector 30'' Below Reflector 30'' 34 inch Patio Plus Reflector |
![]() |
|
| The 34" Patio Plus reflector is the result of extensive testing and research. It's a lot more than just a decorative cover. It has been designed and tested to achieve the highly efficient reflector we use today. The Patio Plus reflector concentrates the radiant energy from the high output infrared burner, into the 20 ft. circle of heat. Stray radiant energy is redirected to the inside of the circle by increasing the intensity of the heating footprint. It has been performance tested by the highly respected Food Service Technology Center in San Mateo, California. Click here to read their testing and findings. | ||
| Patio Plus Outdoor Infra-Red Heaters are made by Easy Radiant Works, a company with more than 30 years experience in the residential commercial and industrial infra red heating industry. All units are 50,000 BTU Propane and Natural Gas | ||
| Patio Plus Infrared Patio Heaters Installation, Operating & Maintenance Instructions |
|||||||||||||
| Download this Document | |||||||||||||
| This appliance is tested and approved for use in winds up to 15 mph. (25 km/hr.) Do not use if wind is exceeding 15 mph. (25 km/hr.) or damage will result. Voiding warranty on heater. The installation of Patio Plus heaters must only be performed by licensed technicians trained and educated in the installation of this type of gas appliance. |
|||||||||||||
| Warning Read this manual completely before first installing or servicing this equipment. Failure to read and fully understand this manual may result in an improper installation, which could cause faulty operation of the heater, property damage, serious injury or death. If you do not fully understand these instructions, contact your Patio Plus representative or the manufacturer prior to the commencement of installation, servicing or maintenance. Easy Radiant Works accepts no responsibility for damages whatsoever resulting in improper installation of this heater. Improper installation voids all warranties. This manual must remain with the heater at all times. For Your Safety: Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. Warning: Improper installation, adjustment, alteration, service or maintenance can cause injury, property damage or death. Read the complete installation manual and all warning labels on the appliance before installation or servicing this equipment. This heater should be installed or serviced by a qualified, licensed gas technician. If you smell gas:
|
|||||||||||||
| Clearances & Safe Mounting Practices | |||||||||||||
![]() Each heater must be installed so that the following “minimum clearances to combustibles” are maintained. Combustible materials are considered to be wood, compressed paper, plant fibres, or other materials capable of being ignited and burned. Such materials shall be considered combustible even though flame-proofed, fire retardant treated or plastered. Additional clearances may be required for glass, painted surfaces, plastics, vinyl and other materials which may be damaged or melted by radiant or convection heat. A minimum clearance of 24 inches (above the heater) must be maintained to plastics, vinyl or any other materials that may be adversely affected by radiant or convection heat. |
|||||||||||||
| Infrared Heat | |||||||||||||
| Patio Plus heaters are effective in heating outdoor spaces because they utilize infrared or radiant heat. Infrared energy is the same type of warmth we get from the sun. Infrared energy warms people and objects without heating the intervening air. Unlike the sun, Patio Plus heaters do not produce Ultraviolet (UV) rays that can be harmful. Infrared energy travels by line-of-sight so the designer must be aware that doors, panels or windows may obstruct the infrared energy from reaching the desired location. Overlapping infrared patterns from numerous heaters may be used effectively to provide even heat distribution. Where multiple heaters are used with the remote switching option it is suggested that they be switched independently, so as to allow for flexibility in heating larger areas as the space becomes occupied by more people. A timer is a good method to ensure that all heaters are turned off when the patio is not being used. Because infrared heaters heat people and objects, and thermostats measure air temperature, a thermostat may not be the best method for controlling outdoor heaters. | |||||||||||||
| Enclosed Patios | |||||||||||||
| Enclosed patios must be large enough to meet the clearance to combustibles, and ventilation requirements as provided for in all applicable codes. For very small- enclosed patios, Patio Plus heaters may not be suitable. DANGER: Patio Plus heaters are not vented to the outdoors. Failure to comply with applicable ventilation requirements could cause serious injury of death. |
|||||||||||||
| Patio Design Considerations | |||||||||||||
| Heater placement is critical for effective and efficient patio heating. If heaters are placed too close together, or mounted too low, patrons of the patio may become uncomfortable. If heaters are placed too far apart, or too high, on a breezy or wind-swept patio, the area may never become comfortable. Infrared heaters work best if placed in areas of greatest heat loss, such as the open side of a semi-protected patio. Windy conditions can be a problem when heating any patio. Windbreaks can be extremely effective in increasing comfort levels. The heating requirements of any patio depend greatly on local climatic conditions. It is recommended that you work with a local and experienced supplier and installer who are familiar with the heating requirements of your area. This product could make carbon monoxide. 400 parts per million of CO for one hour in an unvented room will damage the brain and could cause death. |
|||||||||||||
| Important Safety Rules | |||||||||||||
|
|||||||||||||
| Easy Testing Procedure | |||||||||||||
This product must be assembled and tested as shown in these instructions. Any deviation or lack of testing could cause personal or property damage. Have a qualified professional do it for you. Patio Plus infra red heaters are available for both L.P. and Natural Gas and are approved for indoor & outdoor applications. This appliance must only be used with the fuel for which it was originally labeled. Do not convert this heater to an alternate fuel without first consulting the manufacturer. For indoor use, consult all local applicable codes for unvented appliances before use. These instructions apply to the following Patio Plus models:
Maximum Inlet supply gas pressure: ˝ P.S.I. (14” w.c.) Required manifold pressure: L.P. 10.5” w.c. N.G. 3.5” w.c. Maximum Input 50,000BTU L.P. & 50,000BTU Natural Gas Maximum turn down pressure: 6.4” L.P. & 1.5” Natural Gas |
|||||||||||||
| Choosing a Safe Location | |||||||||||||
| Heaters must be installed on a secure and level surface. Patio Plus heaters may be installed on a combustible surface. If the heater is installed near a combustible wall or under a combustible ceiling, the minimum clearances to combustibles described in the drawing on page 2 must be adhered to. The installation must adhere to all local and applicable codes. In the absence of local codes, it must adhere to current CAN/B149 in Canada or ANSI Z223.1 in the United States | |||||||||||||
| WARNING (Care & Use of L.P. cylinders). L.P. gas cannot be used on units designed for natural gas. Natural gas cannot be used on units designed for L.P. | |||||||||||||
If your heater is designed for use with an L.P. cylinder, the cylinder must meet the following requirements: cylinder weight is 20 lb. (9.07 kg): cylinder has outside diameter of 12-1/8 in. (30.8 cm), length of 18 in. (45.7 cm) and is constructed and marked to specifications of the U.S. Department of Transportation (D.O.T.) or Canadian Transport Commission (C.T.C.). Cylinder has shut-off valve outlet which is a No. 510, female P.O.L.; a safety relief device which has direct communication with vapor space of cylinder. Supply system is arranged for vapor withdrawal. Cylinder includes collar to protect valve. If your heater is to be used on L.P. gas, special precautions should be observed when handling L.P. cylinders. Remember that this is gas and under pressure, which must be handled with care. Ask your L.P. gas dealer to show you the necessary safety precautions and check local codes for use, storage, and transport regulations. Among the recommended practices are:
Always turn off the gas supply to the heater at the cylinder as soon as you are finished using the heater. The L.P. cylinder must be equipped with the pressure regulator and hose assembly supplied with the heater. The pressure regulator is set at the factory for maximum efficiency. Visually inspect the entire length of the hose for damage before use. This requires opening the door of the L.P. cylinder enclosure. If damage or excess wear is found, replace the regulator assembly immediately. If needed, order only factory original parts. Do not attempt to substitute parts. Follow the steps in your assembly instructions book for removing and reinstalling the regulator assembly. Always store L.P. cylinders in a well-ventilated space. If you intend to store the heater indoors, disconnect the L.P. cylinder and store it outside. Disconnected cylinders must have a threaded valve plug tightly installed. When the L.P. cylinder is not disconnected from the heater, the heater and cylinder must be stored outdoors in a well-ventilated space, out of reach of children. If you have not purchased an Auto-Stop Fill Tank, never allow your cylinder to be filled above the liquid level stop fill gauge. The P.O.L. service valve and liquid level gauge are designed to be closed leak-tight by hand. If wrenches are necessary to stop a leak, the valve probably needs repair or replacement. Check all cylinder and line connections periodically to be sure they are tight. Make certain your cylinder is properly fastened in place with the safety strap. |
|||||||||||||
| Assembly Instructions (Portable Models) | |||||||||||||
| PH-45-20-P-LP (Liquid Propane) (for use with 20 lb. propane cylinder)
PH-45-30-P-LP (Liquid Propane) (for use with 20 lb. & 30 lb. propane cylinders). Step 1 Carefully remove all packages from the main packing box. Remove the base assembly from the interior packing box. Gently lift the tank cover off of the base assembly and set aside. For shipping purposes, the heater head is bolted in place, inverted, inside the assembly. Gently rotate the heater head “counterclockwise” until it is free. Discard the metal threaded “T” that is holding the head in place. (See Figure 1) |
|||||||||||||
![]() |
|||||||||||||
| Step 2 Remove the 53” hose from it's packaging and thread the ˝” end into the heater head. A suitably approved pipe thread sealant must be used. Use 2 pipe wrenches to ensure a tight and leak free fit. Remove the 3/8” x 1” bolt from the base of the heater head (Figure 2) and set aside so as not to lose it. Slide the heater head / hose assembly into the 3” post. The top of the post can be identified by the 3/8” hole being at the top end. Line up the 3/8” hole in the post with the 3/8” hole in the base of the heater head, and replace the previously removed 3/8” x 1” bolt. Tighten securely. Step 3 Replace the tank cover so that it sits down in place on the weighted base. Figure 3 Thread flexible hose down through the opening of the post support assembly and stand the post in the assembly. Raise decorative cover to allow access to the tank storage area. Step 4 Secure the regulator to the end of the flexible hose. Use a pipe wrench and suitably approved gas pipe sealant to ensure a tight and leak free connection. Secure coupling nut on regulator into the tank outlet valve on the propane cylinder (cylinder not included). Step 5 Secure the reflector dish to top of the heater head assembly using nuts provided Step 6 Ensure that the heater is used on a secure and level surface, maintaining the clearances to combustibles as outlined on page 2 of this manual. |
|||||||||||||
| Assembly Instructions Model PH-45-FS-LP & Model PH-50-FS-N Free standing model for use will approved flexible supply line. |
|||||||||||||
|
|||||||||||||
| Assembly Instructions | |||||||||||||
| PH-45-FB-LP (Liquid Propane), PH-50-FB-N (Natural Gas), PH-45-FB-R-LP (Liquid Propane & PH-50-FB-R-N (natural gas). Fixed base model for permanent mounting to deck or patio. (“R” indicates heater with remote switching option. Requires switched 24 Volt power supply to heater.) |
|||||||||||||
|
|||||||||||||
| Assembly Instructions (Inground Post Model) | |||||||||||||
|
|||||||||||||
| Assembly Instructions PH-45-H-LP (Liquid Propane) & PH-45-H-R-LP (Liquid Propane) PH-50-H-N (Natural Gas) & PH-50-H-R-N (Natural Gas) Hanging Model - complete with hanging bracket for suspending below an existing supporting structure. |
|||||||||||||
|
|||||||||||||
| Test Firing Heater Leak test all gas connections with soapy water. Soap bubbles indicate gas leakage. Do not use an open flame to test for leaks. Test fire the heater following the lighting instructions on the heater post. To Light Pilot Push and turn the control knob to “PILOT” position. Continue to hold the knob in, and purge air from the system. When air is purged, while depressing the control knob, depress the “spark igniter” button. View the pilot flame through the observation or match lighting hole. Hold the control knob depressed for 45 seconds after lighting. If the pilot does not light, try again. It might need two or three trials to light the pilot burner. Note: for all models allow the required time to safely purge air through pilot after connecting to new gas tank or other system. After pilot is lit and it is mistakenly turned off, the knob will be in an immovable position. Wait 90 seconds and the thermocouple will cool and knob will be released to re-light pilot. To Light Main Burner After pilot is lit, wait 30 seconds and turn the control knob to the “ON” position. Warning Smoke may appear around the emitter grid during the initial firing. This will only happen on the first light up. The oils used in manufacturing are burning off. To Turn Heater and Pilot Off Turn control knob to the “PILOT” position. Depress slightly and turn to the “OFF” position. Wait 5 minutes after shut down before relighting heater. For propane models, turn the propane supply off when heaters are not in use. R-Remote for 24 Volt models (remote switching ON/OFF) Light pilot as above. Turn control knob to the “ON” position. Supply switched 24 Volt power to the 24 V terminal on the heater. Switching 24 Volt power supply ON and OFF will turn main burner ON and OFF. |
|||||||||||||
| Troubleshooting Installation, servicing and maintenance of Patio Plus heaters must only be performed by licensed technicians trained and educated in the installation and servicing of this type of gas appliance. |
|||||||||||||
|
|||||||||||||
| This appliance is tested and approved for use in winds of up to 15 mph (25 km./hr.). Do not use if wind is exceeding 15 mph (25 km./hr.) or damage will result. | |||||||||||||
| In order to protect your heater from wind and the elements, the reflector should be removed and safely stored when the heater is not being used for prolonged periods of time. Cover the exposed heater head with a heavy-duty plastic bag or suitable alternative and seal securely. The reflector should be removed from all portable units if wind exceeds 45 mph. (70 km./hr.). | |||||||||||||
| Maintenance | |||||||||||||
| Keep the heater area clear and free from combustible materials and flammable vapor and liquids. Do not obstruct the flow of combustion and ventilation air. Keep the ventilation opening of the cylinder enclosure clean and free from debris. Visually inspect the burner flame for abnormalities. Warning When storing or packaging 2 or more Patio Plus reflector dishes together, you MUST separate them using suitable material to prevent them from sticking together or damage will occur. Installation, servicing an maintenance of Patio Plus heaters must only be performed by licensed technicians trained and educated in the installation, servicing and maintenance of this type of gas appliance. Guarantee Easy Radiant Works extends a 3-YEAR guarantee from the date of purchase to the original purchaser of this product against manufacturing defects in material and workmanship. If this product fails to operate because of a manufacturing defect, a defective part will be repaired or replaced at Easy Radiant Works' option, if the defective part, along with proof of purchase is sent to Easy Radiant Works. All shipping charges are your responsibility. This guarantee does not apply to defects caused by accidental damage, improper handling, installation, modification, or improper connection to gas source, and specifically excludes liability for indirect, incidental or consequential damage to property. Claims for units, damaged during shipping, must be made at the time of receiving from the carrier. |
View 24v Direct Lite Wiring Diagram
Printable Version
|
|||||
![]() |
|
![]() |